Olab - Testata

EXPANSIONTECH (44000)

2/2 WAYS N.C SOLENOID EXPANSION VALVE WITH INTERCHANGEABLE ORIFICE, DRIVER POSSIBILITY, NBR O.RING AND UL CERTIFIED 36MM COIL IN IP67 H CLASS

EXPANSIONTECH (44000)
CE 28384 AFFIDABILI IP 67

Category: TRADITIONAL REFRIGERATION SYSTEMS

Ways: 2/2 N.C.

Notes:

  • PS: 52 BAR (753 psi)
  • TS: -40°C ÷ +100°C (-40°F ÷ +212°F)
  • CERTIFICATIONS: IP 67, UL

Technical Data Sheet

The EXPANSIONTECH solenoid 2/2-way N.C. expansion valve – Series 44000 is designed for professional A1 refrigeration systems, where precision, inspectability, and modularity are essential.

The yellow brass body is paired with a stainless steel AISI 304 tube, laser-welded in-house by OLAB on a dedicated line to ensure perfect sealing and superior long-term durability.
This valve features a removable and interchangeable stainless steel DN insert, compatible with the full range of available diameters, offering total flexibility during installation or maintenance. An inspectable internal stainless steel filter ensures optimal circuit cleanliness by blocking even the smallest impurities.

The sealing system combines PTFE and dual NBR O-rings, with strategic points of sealing between the body and nozzle, and between the body and tube. 
The 10000BHL coil (36 mm ø14 mm), rated for insulation class H (180°C), includes a double O-ring configuration to ensure excellent thermal isolation. The IP67 protection rating, backed by UL International certification, confirms complete resistance to moisture and dust, guaranteeing reliable performance even in harsh environments. Each valve in the Series 44000 undergoes 100% helium leak testing, and laser marking of the date and serial number provides lifetime traceability of the tested performance. Operating between –40°C and +100°C (–40°F ÷ +212°F) and withstanding pressures up to 52 bar (754 psi), the EXPANSIONTECH valve meets the needs of high-performance, professional-grade refrigeration systems. Fully certified CE, IP67, and UL.  

Technical features:

  • 2/2 ways normally closed solenoid expansion valves
  • Inspectable
  • PTFE seal and NBR O.Ring
  • AISI 304 stainless steel sleeve
  • Yellow brass body
  • 36 mm 10000BHL ø14 coil, insulation class H (180°)
  • UL International certified IP67 protection class
  • Internal stainless steel filter
  • DN with stainless steel insert that can be disassembled, reassembled with the entire DN range available
  • Designed for professional A1 refrigeration systems

COMPATIBLE A1 REFRIGERANT GASES

HFC, HFO e miscele HFO/HFC: R404A, R407C, R410A, R507, R32, R134a
HFO e miscele HFO/HFC: R1234ze, R448A, R449A, R450A, R452A, R1234yf, R1233zd

Our Neoprene compound gaskets have been designed and produced to be compatible with group A1 refrigerant gases (as defined in ASHRAE standard 34).However, in consideration of the infinite application variables (pressure, temperature and mixing percentages), an application check on the system is always required.

DOUBLE NBR O-RING
Guaranteed sealing between both the body and the nozzle, and the body and the tube.

MAXIMUM COIL INSULATION

Achieved with the addition of two O-Rings, one on top and one below.

IP67

Engineered for maximum moisture protection and long-lasting durability.

INTERCHANGEABLE STAINLESS STEEL DN INSERT

Removable and reinstallable, compatible with the entire range of available DN sizes.

MAXIMUM CLEANLINESS

Thanks to the integrated (inspectable) filter, which blocks even the smallest impurities from entering the circuit.

AISI 304 STAINLESS STEEL SLEEVE

Laser-welded in-house at OLAB with a dedicated system, ensuring perfect welds for long-lasting performance and durability.

100% HELIUM TESTED
Each valve is individually tested with pure helium in a dedicated facility. Laser-engraved date and serial number ensure lifetime traceability of recorded performance data.   

Before installing the expansion valve, make sure the refrigeration system is properly clean, though any impurities are intercepted by the filter mounted inside it. An excessive amount of impurities could partially of fully clog the filter, thus reducing its overall performance. The expansion valve can be mounted in all positions, though it is preferable to keep the axis at a right angle with the coil at the top. The direction of the arrow stamped on the valve body must coincide with the direction of flow of the fluid inside the system. Braze welding between the copper pipes and the valve body is performed using low-temperature melting alloys and the presence of seals requires the fitter to pay particular attention in avoiding to direct the flame towards the valve body and sealing areas in general.

DRIVER
DRIVER
close
DRIVER
DRIVER
DIPLAY
DIPLAY
close
DIPLAY
DIPLAY
TRASDUTTORE
TRASDUTTORE
close
TRASDUTTORE
TRASDUTTORE
SONDA
SONDA
close
SONDA
SONDA
10000BHL
10000BHL
close
10000BHL
10000BHL