Category: TRADITIONAL REFRIGERATION SYSTEMS
Ways: 2/2
Notes:
2/2 WAYS NORMALLY CLOSED SOLENOID VALVES
OPENABLE FOR INSPECTION
SEAL IN PTFE AND OR IN NEOPRENE CERTIFIED OLAB
YELLOW BRASS BODY AND COPPER PIPES
Class H coil (180°C)
IP67 PROTECTION CLASS
UL INTERNATIONAL CERTIFIED
DESIGNED FOR PROFESSIONAL REFRIGERATION SYSTEMS
HIGHLY ROBUST, the thickness of the sleeve obtained from AISI 303 stainless steel
machined solid bar is greater than that of traditional tubes obtained from thin
metal sheet
SAFE, approved IP67 UL “INTERNATIONAL PROTECTION” rating
30 MM COIL
Class H
Double OR sealing
100% TESTED, with modern 100% helium plant, each valve bears
the date and serial number proving that it has passed the test and
allowing traceability of the performance data measured during
testing over time
Solenoid valves 30000 series are designed for installation on commercial refrigeration systems on civil and industrial
air conditioning plants that use the following refrigerant fluids belonging to Group 2, as defined in Article 13,
chapter 1, Point (b) of Directive 2014/68/EU, with reference to EC Regulation No. 1272/2008.
See page 19 for more information about refrigerant fluids compatible.
The main construction components of the solenoid valves
of the 30000 series are:
Solenoid valves can be installed anywhere in the system provided that the cooling capacity of all different models is taken into account. The device must be installed ensuring that the refrigerant flows in the direction shown by the arrows on the valve body. All models of this series can be mounted in all positions except for the one with a coil turned downwards. Brazing of valves to weldable pipes must be carried out using an alloy with low melting point. To avoid damages, make sure the flame is not pointed to the body during pipe welding. Before connecting the device make sure the operating data shown on the coil correspond to those on the system. Please read enclosed leaflet before proceeding with the installation.
2/2 WAYS NORMALLY CLOSED SOLENOID VALVES
OPENABLE FOR INSPECTION
SEAL IN PTFE AND OR IN NEOPRENE CERTIFIED OLAB
YELLOW BRASS BODY AND COPPER PIPES
Class H coil (180°C)
IP67 PROTECTION CLASS
UL INTERNATIONAL CERTIFIED
DESIGNED FOR PROFESSIONAL REFRIGERATION SYSTEMS
HIGHLY ROBUST, the thickness of the sleeve obtained from AISI 303 stainless steel
machined solid bar is greater than that of traditional tubes obtained from thin
metal sheet
SAFE, approved IP67 UL “INTERNATIONAL PROTECTION” rating
30 MM COIL
Class H
Double OR sealing
100% TESTED, with modern 100% helium plant, each valve bears
the date and serial number proving that it has passed the test and
allowing traceability of the performance data measured during
testing over time
Solenoid valves 30000 series are designed for installation on commercial refrigeration systems on civil and industrial
air conditioning plants that use the following refrigerant fluids belonging to Group 2, as defined in Article 13,
chapter 1, Point (b) of Directive 2014/68/EU, with reference to EC Regulation No. 1272/2008.
See page 19 for more information about refrigerant fluids compatible.
The main construction components of the solenoid valves
of the 30000 series are:
Solenoid valves can be installed anywhere in the system provided that the cooling capacity of all different models is taken into account. The device must be installed ensuring that the refrigerant flows in the direction shown by the arrows on the valve body. All models of this series can be mounted in all positions except for the one with a coil turned downwards. Brazing of valves to weldable pipes must be carried out using an alloy with low melting point. To avoid damages, make sure the flame is not pointed to the body during pipe welding. Before connecting the device make sure the operating data shown on the coil correspond to those on the system. Please read enclosed leaflet before proceeding with the installation.